ADD TO WISHLIST

Multi V5 VRF 3.2 TR, Ultimate Efficiency, Dual Sensing Control, Ocean Black Fin
See Retailer for Pricing

Limited Quantity Sale

Available QTY 0
  • vip-price-message
    (ARUN040LSH5)
    AED
    AED
    LG Members Price
Total

component-OBScountrySelectDesc

See Retailer for Pricing

Limited Quantity Sale

Available QTY 0
  • vip-price-message
    (ARUN040LSH5)
    AED
    AED
    LG Members Price
Total
Multi V5 VRF 3.2 TR, Ultimate Efficiency, Dual Sensing Control, Ocean Black Fin
  • Quick Operating Response1 Quick Operating Response2

    Quick Operating Response

    Operation response gets faster and more accurate with pressure sensor. Pressure control gets 14% faster in cooling mode, improving user comfort.
  • Optimal Heat Exchanger Circuit 1 Optimal Heat Exchanger Circuit 2

    Optimal Heat Exchanger Circuit

    The variable heat exchanger circuit intelligently selects optimal paths for both heating and cooling operation. This increases efficiency up to 5%.

  • Heat Exchanger with Wide Louver Plus Fin1 Heat Exchanger with Wide Louver Plus Fin2

    Heat Exchanger with Wide Louver Plus Fin

    Heat exchanger efficiency is improved up to 7% with wide louver plus fin by slowing down the frosting and postponing the defrosting operation.

  • World's Best Class Compressor Speed1

    World's Best Class Compressor Speed

    With wider frequency range from 15Hz to 150Hz, MULTI V S improves part load efficiency, enhancing the rapid response capability. The concentrated motor provides compact core design for compressor.

  • High Pressure Compressor1

    High Pressure Compressor

    Due to high temperature and pressure, viscosity of oil is secured, thus there is no need for oil pump. This eventually increases compressor efficiency. 

6 By-pass Valve1

6 By-pass Valve

Compressor reliability is maximized with 6 by-pass valve as it prevents compressor damage caused by excessively compressed refrigerant.
  • Smart Load Control

    MULTI V S controls refrigerant temperature according to indoor, outdoor and setting temperatures. This optimizes energy efficiency by saving up to 13% and maximizes indoor comfort level in cooling/heating modes.

  • MULTI_V_S_06_1525310815780 MULTI_V_S_06_M_1525310821684
CAPACITY
  • *Cooling(Rated) - RT
    3.2
    *Cooling(Rated) - ㎾
    11.2
  • *Cooling(Rated) - Btu/h
    38,200
    **Cooling(Rated) - RT
    2.7
  • **Cooling(Rated) - ㎾
    9.5
    **Cooling(Rated) - Btu/h
    32,400
  • Heating(Rated) - RT
    3.6
    Heating(Rated) - ㎾
    12.5
  • Heating(Rated) - Btu/h
    42,700
INPUT
  • *Cooling(Rated) - ㎾
    2.60
    **Cooling(Rated) - ㎾
    2.80
  • Heating(Rated) - ㎾
    2.75
COP
  • *Cooling - ㎾ / ㎾
    4.31
    **Cooling - ㎾ / ㎾
    3.40
  • Heating - ㎾ / ㎾
    4.55
POWER FACTOR
  • Rated
    0.93
DIMENSIONS (W × H × D)
  • Dimensions(W × H × D) - ㎜
    950 × 834 × 330
    Dimensions(W × H × D) - inch
    37-13/32 × 32-27/32 × 13
POWER SUPPLY
  • Power Supply - Ø, V, Hz
    380-400-415, 3, 50/60
NOTES:
  • 1. Capacities are based on the following conditions:
    - *Cooling : Indoor Temperature 27°C(80.6°F) DB/19°C(66.2°F) WB, Outdoor Temperature 35°C(95°F) DB/24°C(75.2°F) WB
    - **Cooling : Indoor Temperature 27°C(80.6°F) DB/19°C(66.2°F) WB, Outdoor Temperature 46°C(114.8°F) DB/24°C(75.2°F) WB
    - Heating Temperature : Indoor 20°C(68°F) DB / 15°C(59°F) WB, Outdoor 7°C(44.6°F) DB / 6°C(42.8°F) WB
    - Piping Length : Interconnected Pipe Length = 7.5m
    - Difference Limit of Elevation (Outdoor ~ Indoor Unit) is Zero.
    2. The Maximum combination ratio is 130%.
  • 3. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design. Especially the power cable and circuit breaker should be selected in accor- dance with that.
    4. Due to our policy of innovation some specifications may be changed without notification.
  • 5. Sound Level Values are measured at Anechoic chamber. Therefore, these values can be increased owing to ambient conditions during operation.
    6. Power factor could vary less than ±1% according to the operating conditions.
  • Catalog
    • 21_CAC_Retrofit_Sales Guide Book_v10_High.pdf
    • FINAL_AC_Catalogue_ M_Eng_low res.pdf

To access more technical documentation and downloads, please visit the LG B2B Partner Portal.

Find a dealer to help with service for sales, installation, and after sales.
Business Unit is required
Address Unit is required.
  • sales
  • install
  • service
Please retry to enter zip code.

There is no data. Please retry to enter zip code.