Causes and Symptoms
- Vent window for the outdoor unit room is closed.
- Target temperature is set low.
- Filter is severely clogged with dusts.
- Wind angle is adjusted upward.
- Use the Reserve function.
- Outdoor unit is covered with snows.
Try this
Is the vent window or gallery to the outdoor unit room closed?
➔ When using cooling mode, open the ventilation window or gallery in the outdoor unit room so that the heat from the outdoor unit can pass to the outside.
You should adjust the louver angle for the vent window as close to levelness as possible and remove dusts or obstacles at the rear of the outdoor unit.
Did you set the target temperature to 30℃(86°F)?
➔ Set the target temperature to 30℃(86°F) for use.
If temperature is detected at the ceiling, then the measured temperature might differ from the one that
users actually feel indoors.
Set the target temperature high and set the fan speed to strong.
Did you clean the filter?
➔ If the filter is not cleaned for more than one month, then make sure to clean it.
If the filter is severely clogged with dusts, then the amount of air is reduced, thus noises will be louder and the cooling performance will be degraded.
Did you adjust the wind angle?
➔ Adjust the wind angle downward and make sure it is automatically moved up and down.
Hot air goes up to only make the ceiling area warm more quickly, so using the [Wind Angle Adjustment] button to let the wind angle be adjusted downward and press the [Up Down] button to enable auto movement of the louver.
How to adjust the wind angle of the wired remote controller
How to adjust the wind angle of the wireless remote controller
※ Depending on the model of your remote controller, the button location or name might differ.
Did you try to use the reserve function?
➔ On a very cold day, you can use the reserve function to operate the heating machine ahead of time.
Reservation setting(wired remote controller)
Reservation setting(wireless remote controller)
Are there lots of snows on the outdoor unit?
➔ Turn off the air conditioner and remove snows nearby.
If the outdoor unit installed outdoors, then as snow is accumulated on it during heating operation, cooling can get less strong and tends to stop frequently.
If the temperature of sucked in air drops, the temperature of discharged air also drops, thus in case of sudden temperature drop, it might take longer to warn the entire indoor space than usual.