■ Inlet valve is lock from high water pressure. (Water supply pressure must be between 0.05~0.6MPa.)
■ Taps tuned off or low.
■ Too low water pressure.
■ Kinked water supply hose.
■ Inlet hose Filter clogged.
■ Frozen water in the water supply part in winter
■
Recommended
Pressure to reduce dishwasher inlet to is 500KPa (Standard Preset Value).
This assures adequate operation
while maintaining valve below its maximum to reduce stress on the valve.
■ Turn the tap on full then back one turn.
■ If the water pressure is too low, it will be necessary for a plumber to be contacted to have this corrected.
■ Kinked water supply hose.
■ Clean inlet filter with firm brush, such as old toothbrush and re-insert into inlet valve.
■ Melt the frozen part by soaking a towel in warm water and wrapping it around the frozen part. This should allow the unit to operate.