This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. For more information, See our Privacy and Cookie Policy.
This function is disables on your cookie management.
To activate it, click on the link "Edit cookie settings" in the upper
right corner of this page.
LG.com Cookies
We use cookies to offer you a convenient web browsing experience, to suggest personalized ads for you, and to keep improving functions through traffic analysis.
By clicking on ‘ACCEPT ALL’, you consent to our use of cookies. Click ‘Cookie Settings’ to choose whether to accept or disable certain cookies. To find out more, please read our Privacy Policy. | Cookie Settings
These cookies are used to provide you with convenient functions, such as product reviews and product video playback, during your web browsing.
These cookies allows our website to keep improving functions through website traffic analysis and to suggest personalized content for you.
These cookies enable us to show you ads and other content that we think is most attuned to your interests and digital behavior.
This function is disables on your cookie management.
To activate it, click on the link "Edit cookie settings" in the upper
right corner of this page.
R1 Compressor
Efficient and reliable home heating is available by R1 Compressor technology. The improved tilting motion of the scroll has increased overall efficiency and reliability.
ThinQ
With LG ThinQ™ app, users can simply control the heating system anytime from anywhere. Remote access to the heating system allows users maximized comfort.
Intuitive Controller
The intuitive controller allows quick, easy use with a simple touch. Users can set schedules based on their lifestyles and manage energy consumption with daily or monthly power monitoring.
Energy State
LG Therma V has energy-saving power states, can automatically follow power company status signals, and lets your home make and store energy if integrated with our solar and energy storage solutions.
The LG air to water heat pump line-up features various models.
R32 Split | R32 Split | R32 Split | R32 Split | R410A Split | High Temp. | |
---|---|---|---|---|---|---|
Features |
R32 Split 4/6 kW Hydro Box
|
R32 Split 5/7/9 kW Hydro Box
|
R32 Split 4/6 kW IWT
|
R32 Split 5/7/9 kW IWT
|
R410A Split Hydro Box
|
High Temperature
|
Refrigerant & GWP | R32 / 675 | R32 / 675 | R32 / 675 | R32 / 675 | R410A / 2088 |
R410A / 2088 R134a / 1430 |
Capacity Range (kW) | (1Ø) 4 / 6 | (1Ø) 5.5 / 7 / 9 | (1Ø) 4 / 6 | (1Ø) 5.5 / 7 / 9 | (1Ø&3Ø) 12 / 14 / 16 | (1Ø) 16 |
Energy Efficiency Class |
for Heating A+++ / A++ |
for Heating A+++ / A++ |
for Heating A+++ / A++ |
for Heating A+++ / A++ |
for Heating A+++ / A++ |
for Heating A+ / A+ |
Energy Efficiency Class | - | - |
for Water Heating (4/6 kW) A+ |
for Water Heating (5/7/9 kW) A+1) |
- | - |
Power Supply (V, Ø, Hz) | 220-240, 1, 50 | 220-240, 1, 50 | 220-240, 1, 50 | 220-240, 1, 50 |
220-240, 1, 50 380-415, 3, 50 |
220-240, 1, 50 |
Dimension, ODU (WxHxD,mm) |
(4/6kW) 870x650x330 | (5/7/9kW) 950×834×330 | (4/6kW) 870x650x330 | (5/7/9kW) 950×834×330 | 950x1,380x330 | 950x1,380x330 |
Weight, ODU (kg) |
(4/6kW) 44.7 | (5/7/9kW) 60.0 | (4/6kW) 44.7 | (5/7/9kW) 60.0 | (1Ø) 84.8 (3Ø) 85.4 | 89.0 |
Dimension, IDU (WxHxD,mm) |
(4/6kW) 490×850×315 | (5/7/9kW) 490×850×315 | (4/6kW) 600x1,750x660 | (5/7/9kW) 600x1,750x660 | 490x850x315 | 520x1,080x330 |
Weight, IDU (kg) |
(4/6kW) 37.8 | (5/7/9kW) 38.1 | (4/6kW) 118.0 | (5/7/9kW) 118.0 | (1Ø) 40.5 (3Ø) 41.5 | 84.0 |
Sound Power Level ODU (dB(A)) |
(4/6 kW) 57/58 | (5/7/9 kW) 60/60/60 | (4/6 kW) 57/58 | (5/7/9 kW) 60/60/60 | 63/64/65 | 63 |
Sound Power Level IDU (dB(A)) |
(4/6 kW) 44 | (5/7/9 kW) 44 | (4/6 kW) 42 | (5/7/9 kW) 42 | 44 | 58 ~ 63 |
Operation Range (OAT, ℃) |
(4/6 kW) Heating: -20 ~ 35 Cooling: 5 ~ 48 |
(5/7/9 kW) Heating: -25 ~ 35 Cooling: 5 ~ 48 |
(4/6 kW) Heating: -20 ~ 35 Cooling: 5 ~ 48 |
(5/7/9 kW) Heating: -25 ~ 35 Cooling: 5 ~ 48 |
Heating: -25 ~ 35 Cooling: 5 ~ 48 |
Heating: -25 ~ 35 |
Operation Range (LWT, ℃) |
(4/6 kW) Heating: 15~55 Cooling: 5~27(16~27)2) |
(5/7/9 kW) Heating: 15~65 Cooling: 5~27(16~27)2) |
(4/6 kW) Heating: 15~55 Cooling: 5~27(16~27)2) |
(5/7/9 kW) Heating: 15~65 Cooling: 5~27(16~27)2) |
Heating: 15 ~ 57 Cooling: 5 ~ 27 (16 ~ 27)2) |
Heating: 25 ~ 80 |
Operation Range (LWT, ℃) | (4/6 kW) DHW: 15 ~ 803) | (5/7/9 kW) DHW: 15 ~ 804) | (4/6 kW) DHW: 15 ~ 803) | (5/7/9 kW) DHW: 15 ~ 804) | DHW: 15 ~ 803) | DHW: 25 ~ 80 |
Model Name (ODU, 1Ø) |
(4/6 kW) HU041MR U20 HU061MR U20 |
(5/7/9 kW) HU051MR U44 HU071MR U44 HU091MR U44 |
(4/6 kW) HU041MR U20 HU061MR U20 |
(5/7/9 kW) HU051MR U44 HU071MR U44 HU091MR U44 |
HU121MA U33 HU141MA U33 HU161MA U33 |
HU161HA U33 |
Model Name (ODU, 3Ø) |
- | - | - | - |
HU123MA U33 HU143MA U33 HU163MA U33 |
- |
Model Name (IDU) |
(4/6 kW) HN0613M NK5 |
(5/7/9 kW) HN091MR NK5 |
(4/6 kW) HN0613T NK0 |
(5/7/9 kW) HN0913T NK0 |
HN1616M NK5 HN1636M NK5 |
HN1610H NK3 |
Features |
---|
Refrigerant & GWP |
Capacity Range (kW) |
Energy Efficiency Class |
Energy Efficiency Class |
Power Supply (V, Ø, Hz) |
Dimension, ODU (WxHxD,mm) |
Weight, ODU (kg) |
Dimension, IDU (WxHxD,mm) |
Weight, IDU (kg) |
Sound Power Level ODU (dB(A)) |
Sound Power Level IDU (dB(A)) |
Operation Range (OAT, ℃) |
Operation Range (LWT, ℃) |
Operation Range (LWT, ℃) |
Model Name (ODU, 1Ø) |
Model Name (ODU, 3Ø) |
Model Name (IDU) |
R32 Split | R32 Split | R32 Split | R32 Split | R410A Split | High Temp. |
---|---|---|---|---|---|
R32 Split 4/6 kW Hydro Box
|
R32 Split 5/7/9 kW Hydro Box
|
R32 Split 4/6 kW IWT
|
R32 Split 5/7/9 kW IWT
|
R410A Split Hydro Box
|
High Temperature
|
R32 / 675 | R32 / 675 | R32 / 675 | R32 / 675 | R410A / 2088 |
R410A / 2088 R134a / 1430 |
(1Ø) 4 / 6 | (1Ø) 5.5 / 7 / 9 | (1Ø) 4 / 6 | (1Ø) 5.5 / 7 / 9 | (1Ø&3Ø) 12 / 14 / 16 | (1Ø) 16 |
for Heating A+++ / A++ |
for Heating A+++ / A++ |
for Heating A+++ / A++ |
for Heating A+++ / A++ |
for Heating A+++ / A++ |
for Heating A+ / A+ |
- | - |
for Water Heating (4/6 kW) A+ |
for Water Heating (5/7/9 kW) A+1) |
- | - |
220-240, 1, 50 | 220-240, 1, 50 | 220-240, 1, 50 | 220-240, 1, 50 |
220-240, 1, 50 380-415, 3, 50 |
220-240, 1, 50 |
(4/6kW) 870x650x330 | (5/7/9kW) 950×834×330 | (4/6kW) 870x650x330 | (5/7/9kW) 950×834×330 | 950x1,380x330 | 950x1,380x330 |
(4/6kW) 44.7 | (5/7/9kW) 60.0 | (4/6kW) 44.7 | (5/7/9kW) 60.0 | (1Ø) 84.8 (3Ø) 85.4 | 89.0 |
(4/6kW) 490×850×315 | (5/7/9kW) 490×850×315 | (4/6kW) 600x1,750x660 | (5/7/9kW) 600x1,750x660 | 490x850x315 | 520x1,080x330 |
(4/6kW) 37.8 | (5/7/9kW) 38.1 | (4/6kW) 118.0 | (5/7/9kW) 118.0 | (1Ø) 40.5 (3Ø) 41.5 | 84.0 |
(4/6 kW) 57/58 | (5/7/9 kW) 60/60/60 | (4/6 kW) 57/58 | (5/7/9 kW) 60/60/60 | 63/64/65 | 63 |
(4/6 kW) 44 | (5/7/9 kW) 44 | (4/6 kW) 42 | (5/7/9 kW) 42 | 44 | 58 ~ 63 |
(4/6 kW) Heating: -20 ~ 35 Cooling: 5 ~ 48 |
(5/7/9 kW) Heating: -25 ~ 35 Cooling: 5 ~ 48 |
(4/6 kW) Heating: -20 ~ 35 Cooling: 5 ~ 48 |
(5/7/9 kW) Heating: -25 ~ 35 Cooling: 5 ~ 48 |
Heating: -25 ~ 35 Cooling: 5 ~ 48 |
Heating: -25 ~ 35 |
(4/6 kW) Heating: 15~55 Cooling: 5~27(16~27)2) |
(5/7/9 kW) Heating: 15~65 Cooling: 5~27(16~27)2) |
(4/6 kW) Heating: 15~55 Cooling: 5~27(16~27)2) |
(5/7/9 kW) Heating: 15~65 Cooling: 5~27(16~27)2) |
Heating: 15 ~ 57 Cooling: 5 ~ 27 (16 ~ 27)2) |
Heating: 25 ~ 80 |
(4/6 kW) DHW: 15 ~ 803) | (5/7/9 kW) DHW: 15 ~ 804) | (4/6 kW) DHW: 15 ~ 803) | (5/7/9 kW) DHW: 15 ~ 804) | DHW: 15 ~ 803) | DHW: 25 ~ 80 |
(4/6 kW) HU041MR U20 HU061MR U20 |
(5/7/9 kW) HU051MR U44 HU071MR U44 HU091MR U44 |
(4/6 kW) HU041MR U20 HU061MR U20 |
(5/7/9 kW) HU051MR U44 HU071MR U44 HU091MR U44 |
HU121MA U33 HU141MA U33 HU161MA U33 |
HU161HA U33 |
- | - | - | - |
HU123MA U33 HU143MA U33 HU163MA U33 |
- |
(4/6 kW) HN0613M NK5 |
(5/7/9 kW) HN091MR NK5 |
(4/6 kW) HN0613T NK0 |
(5/7/9 kW) HN0913T NK0 |
HN1616M NK5 HN1636M NK5 |
HN1610H NK3 |
Monobloc
• Simple all-in-one solution
• Heating, cooling and hot water supply
• A+++ energy class (average climate at 35℃ water outlet)
• Leaving water temperature up to 65 ℃
• Works at outdoor temperature as low as -25 ℃
• No indoor space for indoor unit needed
• Safe indoor environment from leaking refrigerant.
Hydrosplit
• Only water passes through the home
• Heating, cooling and hot water supply
• A+++ energy class (average climate at 35℃ water outlet)
• Leaving water temperature up to 65 ℃
• Works at outdoor temperature as low as -25 ℃
• Outdoor unit connects to indoor unit by water piping
• Wall-mounted hydro box or floor-standing integrated water tank type indoor unit