Find helpful information about your LG Product through our Help Library. Find helpful information about your LG Product through our Help Library.

Help Library

Find helpful information about your LG product

[LG Air Conditioner Error Code][Wall-Mounted] CH and 61 alternatively blink on the display

Troubleshooting

[Cooling] Inspection code of error CH 61 can be displayed to protect the product when the temperature of the evaporator of the outdoor unit rises high.
[Heating] Error code CH61 may appear if the temperature inside the indoor unit rises high because of thick layer of dusts on the indoor unit filter.

Causes and Symptoms

[Cooling]

  • The window of the outdoor unit chamber is closed.
  • Obstacles are stacked around the outdoor unit to interrupt ventilation.
  • Error code CH61 does not disappear from the display.

[Heating]

  • The indoor unit filter is covered with thick layer of dust.

[Cooling]
Error code CH61 appears when the temperature in the outdoor unit rises high during the cooling mode.
If the place of the outdoor unit is not well ventilated, hot air does not exhaust out of the building, and the temperature in the outdoor unit chamber rises high.
The error code is displayed for preventing fire and product failure.

[Heating]
Error code CH61 appears if the temperature inside the indoor unit rises high during operation of the air conditioner in the heating mode.
The error code appears if outdoor is not well inhaled into the indoor unit. The major cause is contamination of the indoor unit filter.

Try this

[During cooling mode] Is the ventilation window of the outdoor unit chamber closed?

➔ Open the ventilation window or the mosquito net.

If the temperature in the outdoor unit chamber rises high, hot air may flow into the air conditioner.
Open the window or the ventilation window of the outdoor unit chamber.

Open the window or the ventilation window of the outdoor unit chamber.
Wait! Find out more.
Keep the louver of the ventilation window horizontal as possible.
Keep the louver of the ventilation window horizontal as possible.

Are there a number of obstacles around the outdoor unit?

➔ Remove obstacles around the outdoor unit to ensure good ventilation.

If obstacles are stacked around the outdoor unit, hot air from the outdoor unit is not discharged out of the building.
Hot air from the outdoor unit returns into the outdoor unit back.
In such a case, the air conditioner operate under overload to cause higher electric bill and degrading of cooling capability.
Remove obstacles from the front, the sides and the rear of the outdoor unit for ensuring sufficient ventilation.

Keep the louver of the ventilation window horizontal as possible.

Is the outdoor unit installed at height lower than the ventilation window?

➔ Keep the outdoor unit aligned with the ventilation window.

If the outdoor unit is installed at height lower than the ventilation window, some of hot air is not discharged out of the building.
It is desirable to install a stand under the outdoor unit to keep the outdoor unit parallel with the ventilation window.
Installing the stand will be charged.

Keep the outdoor unit aligned with the ventilation window.

Is the distance between the outdoor unit and the ventilation window great?

➔ If it is hard to move the outdoor unit, install an air guide.

If the distance between the outdoor unit and the ventilation window too great, ventilation becomes poor, and the temperature inside the outdoor unit chamber may rise high.
In such a case, install an air guide to let hot air from the outdoor unit directly discharged out of the building.

install an air guide.
Wait! Find out more.
The experiment results of LG Electronics indicate that installing an air guide drops the temperature inside the outdoor unit chamber by approximately 6℃ to 8℃.
Air guides are available at nearby hardware stores, or Internet shopping mall.

[During heating mode] Is the indoor unit filter covered with thick layer of dusts?

➔ Clean the indoor unit filter.

Error code CH61 is not released by itself, and you should turn the power off, and start the product 3 minutes later.
Error code CH61 is not released by itself.
If the error takes place, reset the power of the air conditioner.
Unplug the power cord, and then plug it in 3 minutes later.

Unplug the power cord, and then plug it in 3 minutes later.

If there is no power plug, trip the circuit breaker, and then reset it 3 minutes later.

※ If Error code CH61 persistently appears after power resetting, have the service manager check the product.

This guide was created for all models, so the images or content may be different from your product.

*Required question