[LG Air Conditioner Installation] [Portable] I want to know the installation materials. (Released after 2020/2021)

Troubleshooting

Causes and Symptoms

  • Installation materials are different between products released in 2020 and those in 2021.

Standard installation materials

2020 Installation Materials List
Discharge hose (max. 1.5M/4.92ft)
1 standard installation stand (90cm/354.33in)
1 extended installation stand A (65cm/25.59in)
1 extended installation stand B (110cm/43.30in)
2 bolts, 3 nuts
4 side insulations (2.5x0.5cm/0.98x0.19in)
2 widow gap insulations (3.5x1.5cm/1.37x0.59in)
2 20mm/0.78in insulations, 1 40mm/1.57in insulation
2 adhesion insulations
2 brackets for window securing, and screws each
2021 Installation Materials List
Discharge hose (max. 1.7M/5.57ft)
1 standard installation stand (90cm/35.43in)
1 extended installation stand A (65 cm/25.59in)
1 extended installation stand B (110 cm/43.30in)
2 installation stand holders
2 window holders
3 side gaskets A (85cm/33.46in)
3 side gaskets B (85cm/33.46in)
2 window gap insulations (3.5x3.5cm/1.37x1.37in)
2 adhesion insulations
2 brackets for window securing, and screws each
1 slide lock

Assembling the installation stand according to the chassis length

➔ Released in 2021

2021 Installation Panel Specification and Example of Installation Panel Assembly
Height of the window chassis : 90cm(35.43in)~153cm(60.23in) (standard option), Standard installation stand (90 cm)(35.43in), Extended installation stand (65 cm)(25.59in)
Height of the window chassis : 153cm(60.23in) to 198cm(77.95in), Standard installation stand (90 cm)(35.43in), Extended installation stand (110 cm)(43.30in)
Height of the window chassis : 198cm(77.95in) to 261cm(102.75in), Standard installation stand (90 cm)(35.43in), Extended installation stand (65 cm)(25.59in), Extended installation stand (110 cm)(43.30in)

➔ Product released in 2022 and thereafter

Installation Panel Specifications and Installation Panel Assembly Examples Released Since 2021
Height of the window chassis : 35.03~57.08(in), Standard installation stand (890mm)(35.03in), Extended installation stand (590mm)(23.22in)
Height of the window chassis : 57.08~77.16(in), Standard installation stand (890mm)(35.03in), Extended installation stand (1100mm)(43.30in)
Height of the window chassis : 77.16~99.21(in), Standard installation stand (890mm)(35.03in), Extended installation stand (590mm)(23.22in), Extended installation stand (1100mm)(43.30in)

Dimensions of the installation stand and the connection

Image of 20 Year Installation Panel Size Guide Image of installation plate size after 21 years
Same installation plate connection size after 20 years
Wait! Here are more tips.
Q. It is possible to use the installation stands of the products released after 2021 on those released in 2020?
A. Yes, it is.
Q. The length of the discharge hose is short. There is an optional 2-M extension hose. Is the hose compatible?
A. Yes, it is. (Part No. of optional hose: MEJ64164703. The hose is available at the service center.)

If it is required to modify any of the installation materials

If the height of the window frame is 90 cm (35.43in) or smaller, you can modify the installation stand as follows: (Required tools: Tape measure, saw, drill)

Warning!

Once the installation kit is cut, the kit is not restored, and it is not possible to install the product with the extended installation stand in such a case.

➔ Standard installation stand (90 cm/ 35.43in)

  • Cut the stand by required length.
  • Cut the stand in length shorter than the height of the window frame by 1.5-2.0cm (0.59~0.78in) to secure a space for attachment of the window frame holder of the installation kit.
    Example: If the height of the window frame is 80cm (31.49in), cut the installation stand in length of 78cm (30.70in). / Required tool: Tape measure
Cut the installation plate to a -2cm(0.78in) saw at the height of the window frame / Cannot be restored after cutting

➔ Discharge hose

  • The maximum length is 1.7m(5.57ft).
  • The 2m(6.56ft) discharge hose is optional, and available at the service center. (Part No.: MEJ64164703)
  • Modifying and extension of the discharge hose are not possible.
  • Replacement of damaged discharge hose is only allowed.
    The discharge hose should be installed as short as possible to keep cooling capability minimal, and efficiency maximal.
    Note, however, that the least distance between the product and the wall should be secured.
Exhaust hose image
Guide for replacement of the discharge hose

1. Turn the parts on the both ends clockwise to remove them.

2. Extend the both ends of the replacement intermediate part by 3 to 4 pitches.

3. Turn the parts on the both ends counterclockwise to assemble them.
(It is allowed to turn the intermediate hose to disassemble and assemble it if the bottom part is not removed.)

Image to be disassembled when replacing the exhaust hose

This guide was created for all models, so the images or content may be different from your product.

*Required question