LG Dryer – Proper Venting and Installation Tips

  • Operation

At a Glance

When installing your LG dryer, it is important to properly install your dryer vent to maximize dryer performance and prevent any issues from occurring.

Try This

Ductwork Requirements


1The exhaust duct should be as short as possible.

2Verify the exhaust hose is completely straight or in an S curve. (pictured below).

Image showing dryer vent in an S shape

3Ensure the exhaust duct is not kinked, crushed, or dented.

4Avoid using plastic or vinyl ducting.

Image showing rigid, and semi rigid duct

Ventilation System Requirements

The maximum run for the home ventilation should not exceed 65 ft. Deduct 6 ft. (1.8 m) for each additional elbow.

Note

Do not use more than four 90° elbows.

Wall Cap Type and Number of Elbows Allowed
Wall Cap Type Number of 90° elbows Maximum Length of 4-Inch (10.2cm) diameter rigid metal duct
Recommended wall cap have a 4 inch or 10.2cm opening 0 65 ft.(19.8m)
1 55 ft.(16.8m)
2 47 ft(14.3m)
3 36 ft.(11.0m)
4 28 ft.(8.5m)
For short runs you can use 2 1/2 or inch 6.35cm openings. 0 55 ft.(16.8m)
1 47 ft(14.3m)
2 41 ft(12.5m)
3 30 ft.(9.1m)
4 22 ft.(6.7m)